AWG wire gauge converter

Convert between AWG wire size, diameter and cross-section, with resistance and ampacity.

Input
Output

AWG wire gauge converter

Paste a list of wire sizes and this tool converts each one between American Wire Gauge (AWG), diameter in millimeters and cross-sectional area in mm², one line at a time. It's built for electricians, hobbyist electronics builders and anyone reading a datasheet or a US cable spec who needs the metric numbers behind an AWG rating — or the other way around, sizing a project against wire that's only labeled in AWG.

Choose which quantity you're entering with "Convert from", then pick copper or aluminum and a conductor temperature rating (60 to 105 °C) — both affect the resistance per kilometer and the indicative current-carrying capacity shown alongside every result. The installation method (free air, conduit or bundled with other cables) derates that capacity the way real wiring runs do: bundled cables run hotter for the same current. "Nearest standard size" controls whether an in-between result — say, a diameter that falls between two AWG numbers — rounds to the closer standard gauge, or always up or down, which matters when you're picking a wire that has to be big enough rather than merely close enough.

Sizes below 1 AWG are shown the conventional way — 0, 00, 000 and 0000 rather than negative numbers. Turn on "Output as table" for a column-aligned view when converting a whole list, and switch off "Convert every line" to stop after the first recognized value. A line with no number, or a diameter/area that isn't a positive value, is left untouched and flagged rather than guessed at. Ampacity here is an indicative estimate from a simplified physical model, not a substitute for a certified wiring table.

Everything runs locally in your browser — no wire list or project detail is ever uploaded. Copy the result, download it as a .txt file, or send the output straight back into the input to convert again with different options.

FAQ

How accurate is the current-carrying capacity figure?
It is an indicative estimate from a simplified heat-dissipation model, useful for a rough sanity check. For a real installation, use a certified ampacity table or check with a qualified electrician.
Why does the same wire show a different resistance at a different temperature?
Resistance rises with conductor temperature. The tool applies the standard temperature coefficient for copper or aluminum, referenced to 20 °C, so the figure reflects the operating temperature you select.
What do "00", "000" and "0000" mean?
Those are the conventional names for AWG sizes larger than 0 — sometimes called "aught" sizes. Each extra zero is one standard size bigger; 0000 (4/0) is the largest this tool converts.
Can I convert a mix of AWG, mm and mm² values at once?
Each run uses one "Convert from" unit for the whole list, since a bare number has no unit attached. Run the list again with a different setting for a different unit.
Is my wire list uploaded anywhere?
No. Every conversion runs locally in your browser — nothing you paste here is sent to a server.